The LH Series of Hydrostatic pressure and level transmitters are designed for pressure measurement for liquids across a wide range of industrial processes. Each model provides excellent stability, repeatability and accuracy, with both temperature and atmospheric compensation. Output options include 4-20mA, 1-5volts, 1-10volts and HART communication protocol.
- The LH840 features a 316SS piezoresistive sensor, 316SS body, a polypropylene vented cable and pressure ranges from 0…1 bar to 600bar.
- The LH840S features a 316SS piezoresistive sensor, with 5/8” diameter narrow 316SS body, a polypropylene vented cable and pressure ranges from 0..1bar to 600bar.
- The LH850 features a 316SS piezoresistive sensor, 316SS body, a polypropylene vented cable and pressure ranges from 0…1 bar to 600bar.
- The LH860 features a thin filmed piezoresistive ceramic sensor, a 316SS or PVC body, a polypropylene vented cable and pressure ranges from 0…1 bar to 600bar.
- The LH840C features a thick film capacitive ceramic sensor, 316SS or all PVC body, pressure ranges from 0…300bar and optional HART protocol.
- The LH842 features a Zero and Span adjustment, 316SS piezoresistive silicon sensor, 316SS body, pressure ranges from 0…300bar and optional HART protocol.
- The LH842C features a Zero and Span adjustment, thick film capacitive ceramic sensor, 316SS or all PVC body, pressure ranges from 0…300bar and optional HART protocol.
Hidrostatic Level Transmitter
Application: | Level Measurement for Liquids |
Operating Voltage: | 12...30Vdc |
Consumption: | Max 22mA |
Output Signal: | 4...20mA (2 wires) with HART Protocol (optional) |
Accuracy: | Max error of 0,5% |
Sensor: | Capacitive and Piezo Ceramic / 316S.S Piezoresitive |
Measurement Range: | Capacitive Ceramic: 0 to 40 Bar (Cable) / 0 to 0.3 Bar (Rod) , Piezo Ceramic: 0 to 60 Bar / 316S.S: 0 to 60 Bar |
Electrical Connection: | LH842: Cable Gland 1/2" NPT / M12 Connector / LH840: Polythene cables 2(wires) with vented tube |
Processo Connection: | LH842: BSP or NPT, Flange, Sanitary, Rigid rod or Cable/ LH840: polythene cable with vent tube |
Body Material: | 316S.S |
Class Protection: | IP68 (IEC 60529) |
Documentation for download
- Water and Waste Water Utilities
- Sump or River Level Monitoring
- Sanitary Process Level Measurement
- Food and Beverage applications
- Pulp and Paper Industry